When it concerns guaranteeing safety in industrial, commercial, and residential spaces, slip resistance testing is an important factor. At ATTAR (Advanced Technology Testing & Research), we focus on floor slip resistance testing, concrete moisture testing, and luminance contrast analysis to assist businesses and property owners alleviate risks and abide by safety requirements.
With cutting edge equipment such as the pendulum slip test maker and moisture meter for concrete, we provide accurate and independent slip testing services throughout Australia. Our knowledge covers ASTM F2170 compliance, R Ranking assessments, P Ranking tiles, and more, ensuring your floors satisfy the greatest security standards.
Why Slip Resistance Testing is Essential
Slips and falls are among the leading reasons for office and public injuries. Proper slip testing helps identify dangerous surface areas before mishaps take place. Whether you need wet pendulum test examinations or pendulum test for slip resistance, ATTAR provides exact outcomes to boost safety.
Key Services Provided by ATTAR
1. Floor Slip Resistance Testing
- Pendulum slip test (AS 4663).
- R Score and P Score tiles assessments.
- Independent slip testing services for compliance.
2. Concrete Moisture Testing
- Slab moisture test utilizing advanced moisture meter for concrete.
- ASTM F2170 certified evaluations.
- Concrete slab moisture testing to prevent flooring failures.
3. Luminance Contrast Testing
- Makes sure exposure for visually impaired people.
- Complies with Australian ease of access requirements.
4. On-Site & Laboratory Testing
- Slip test device for accurate on-site evaluations.
- Wet pendulum test for wet surface area slip resistance.
Comprehending Slip Resistance Rankings: R Ranking vs. P Ranking
When carrying out slip resistance testing, 2 essential classifications are used:.
- R Rating (Ramp Test - DIN 51130)
Measures slip resistance under lubricated conditions, commonly utilized in Europe.
- P Ranking (Pendulum Test - AS 4586)
Evaluates dynamic friction using a pendulum test slip resistance machine, extensively embraced in Australia.
ATTAR supplies independent slip testing to figure out whether your floor covering satisfies the needed pendulum rating tiles standards.
The Value of Concrete Moisture Testing
Excess moisture in concrete slabs can cause flooring failures, mold growth, and adhesive destruction. Our concrete moisture testing services consist of:.
> ASTM F2170 certified in-situ relative humidity testing.
> Moisture meter for concrete assessments.
> Slab moisture test to ensure optimal conditions for floor setups.
By identifying moisture concerns early, we assist prevent pricey repair work and guarantee long-lasting floor covering efficiency.
Luminance Contrast for Ease Of Access Compliance
Appropriate luminance contrast is essential for aesthetically impaired people to navigate areas securely. ATTAR evaluates:.
> Stair edges.
> Door frames.
> Handrails.
> Tactile indicators.
Our evaluations make sure compliance with Australian Impairment Standards (AS 1428.1).
Why Choose ATTAR for Slip Resistance & Moisture Testing?
> NATA Accredited (where relevant).
> Advanced Testing Equipment (pendulum slip test, moisture meters).
> Nationwide Service Coverage.
> Fast & Trusted Reporting.
For skilled slip resistance testing, floor slip resistance testing, and concrete moisture testing, contact ATTAR (Advanced Technology Testing & Research):.
Address: 44/48 Rocco Dr, Scoresby VIC 3179, Australia.
Phone: +61 1300 139 155.
Typical Applications of Slip Resistance Testing
1. Commercial & Retail Spaces
Shopping centres, restaurants, and workplaces require safe flooring to prevent client and worker injuries. Our pendulum slip test ensures compliance with security regulations.
2. Industrial & Storage Facility Facilities
High-traffic industrial environments require durable, slip-resistant flooring. ATTAR's slip testing services assist keep workplace safety.
3. Health Care & Aged Care Facilities
Health centers and retirement home should reduce slip risks. Our luminance contrast and slip resistance testing make sure safe mobility for clients and personnel.
4. Public Infrastructure
Walkways, train stations, and government buildings need independent slip testing to satisfy availability and safety requirements.
How ATTAR Conducts Slip Resistance Testing
Action 1: Surface Evaluation
We evaluate floor covering products and conditions (dry, wet, or polluted).
Action 2: Pendulum Slip Test (AS 4663)
Using a slip test maker, we determine the dynamic coefficient of friction (DCOF).
Action 3: Wet Pendulum Test
Simulates slippery conditions to evaluate real-world slip threats.
Step 4: Reporting & Compliance Accreditation
Comprehensive reports with R Score or P Score tiles categories.
The Science Behind Pendulum Slip Testing
The pendulum test slip resistance method involves a swinging arm with a rubber slider that simulates a foot's movement. The test procedures:.
- Slip Potential Worth (SPV).
- Pendulum rating tiles classification (P0 to P5).
Greater scores (P4/P5) suggest read more better slip resistance.
Moisture Testing for Concrete Floors: Preventing Failures
Moisture-related floor covering failures can be pricey. ATTAR's concrete slab moisture testing includes:.
- ASTM F2170 in-situ RH probes.
- Moisture meter for concrete check.
- Slab moisture test data analysis.
Conclusion
ATTAR (Advanced Technology Testing & Research) is Australia's relied on provider of slip resistance testing, floor slip resistance testing, concrete moisture testing, and luminance contrast evaluations. With innovative technology like the pendulum slip test and moisture meter for concrete, we deliver accurate, independent, and certified testing services.
Guarantee your property satisfies safety standards-- contact ATTAR today:.
44/48 Rocco Dr, Scoresby VIC 3179, Australia.
+61 1300 139 155.
By picking ATTAR, you invest in independent slip testing services, pendulum test slip resistance accuracy, and long-lasting floor security options. Let us assist you develop more secure, compliant, and moisture-resistant environments. Report this page